The APD modules are based on low-noise avalanche photodiodes made of InGaAs with a built-in pre-amplifier and high voltage supply.A temperature compensation function allows the APD to be operated at constant gain across a wide operating temperature range.
Fiber grating demodulator module, the wavelength range from 1525nm to 1567nm, can be used with a variety of fiber grating sensors, through the detection of grating wavelength changes to achieve the purpose of monitoring temperature, strain, pressure and other physical quantities.
This is a 1450/1550/1660nm Raman WDM coupler module for DTS Raman temperature measurement system, with one 1550nm input port and three output ports (1450nm and 1660nm to APD photodetector, COM port to sensing optical cable.
This module makes DTS system integration more convenient.
The laser is customized for distributed fiber optic temperature measurement applications and features high stability, adjustable pulse width and high peak power output at 1550 nm with a minimum pulse width of 5 ns. It supports both ACC and APC mode operation.
From the schematic diagram we can see that the distributed fiber optic vibration data monitoring system, using a balanced photodetector for coherent detection, and then need to IQ demodulation of the collected data, demodulation followed by phase unwinding to obtain the amplitude root phase data information.
Introduces the configuration of the pulsed laser for DTS temperature sensing, including how to set the ACC and APC modes, the trigger method and the pulse width parameters.
Coherent Detection Module for Distributed Fiber Optic Vibration/Sound Detection (DVS/DAS) and Wind Radar.It is characterized by high signal-to-noise ratio, high reliability and easy integration.
DVS-A series DVS all-in-one integrated module each channel can support 40km. data output for 2-way Gigabit network port, built-in fiber optic sensing demodulation algorithm.
Introduction of data acquisition card for distributed fiber optic vibration monitoring system, 100M sampling rate, PCIe interface with demodulation algorithm.
How long can a distributed fiber optic vibration sensing system monitor? In the laboratory it can support 80km, in the application site to consider the light decay and other reasons, the maximum available 60km.
The spatial resolution is related to your optical pulse parameter setting, which is set according to the monitoring length of the fiber optic cable. 40km distance we can achieve 5m spatial resolution.
The software programming of DVS/DAS system is actually for the interface programming of data acquisition card, you can use C, C++, Python, labview, matlab, etc. for programming.
The type of fiber used for distributed fiber optic vibration sensing is single-mode G652, which is a very common fiber, all in our communication fiber optic cable, and is not expensive.